The physical characteristic primarily responsible for shifting a battery's performance curve toward the power density axis on a Ragone plot is low internal resistance. A Ragone plot displays energy density on the y-axis and power density on the x-axis, illustrating the trade-off between the total energy a battery can store and the rate at which it can deliver that energy. Internal res....